Answer: The E for Silver-silver Chloride electrode = 0.287 V
Explanation:
Silver/Silver Chloride (Ag/AgCl) with a value for E° that is actually +0.222 V or approximately 0.23 V has the actual potential of the half-cell prepared in this way as +0.197 V vs SHE, (Standard Hydrogen Electrode) which arises because in addition to KCl, there is the contribuion of AgCl to the chloride activity, which isn't exactly unity.
Therefore, the E for the Ag/AgCl electrode would approximately equal 0.287 V